Gas here runs $21.08 per million Btu
Rhode Island gas cost homes $21.08 per million Btu in 2024, among the higher rates in the country. A boiler that wastes heat burns through more gas at that price, every month it runs.

Takes about a minute. No obligation.
Rhode Island gas cost homes $21.08 per million Btu in 2024, among the higher rates in the country. A boiler that wastes heat burns through more gas at that price, every month it runs.
A boiler's efficiency rating says how much of the gas it burns turns into heat for the house, and how much goes out the flue. At Rhode Island gas prices, a few points of efficiency change what the boiler costs to run all winter.
Utility gas heats 60.9% of homes in Providence County, more than any other fuel.
A gas boiler here replaces a system most of this area already has, with a gas line already run to the house.



Half the homes in Providence County were built in 1956 or earlier. A boiler going into a house that age is going into a heating system that was probably sized for radiators or baseboards already in place, with pipes and returns that were never changed. The new boiler has to match what those pipes can carry, not just the square footage of the house. This is where a contractor walking through the house matters more than any spec sheet. Get the size wrong and the boiler either short cycles or can't keep up on the coldest nights.
Providence County sits in climate zone 5A, a cool zone where heating carries most of the load. Any gas boiler installed now has to reach at least 84 percent AFUE, so that part of the decision is already made. A federal tax credit is available for qualifying high-efficiency equipment, worth asking a contractor about when you're comparing models.
Find a contractorThe rating on the label is measured under set conditions in a lab. In the house it will run a little higher or lower depending on the day, the return water temperature, and how the system is piped. A boiler rated near the minimum will still heat the house fine. It just burns more gas doing it than one rated higher.
A low-efficiency boiler and a high-efficiency one can heat the same radiators to the same temperature. The difference is how much of the gas you're paying for actually ends up in that heat, versus how much goes straight out the vent. That gap doesn't change with how new the boiler looks or how it's installed. It's built into the unit itself.
A few questions tell you more than the spec sheet does. Ask what happens to the existing piping and whether it needs new zone valves or a different pump to match the new boiler's flow rate. Ask whether the venting changes. A higher efficiency boiler often vents through the sidewall with plastic pipe instead of running up a chimney, and that changes where it can sit in the house. Ask how the contractor is sizing it, and make them walk you through the heat loss calculation rather than just matching the old boiler's rating. Ask what the warranty covers on the heat exchanger versus the rest of the unit, since those terms are often different. And ask what maintenance the boiler needs each year to hold onto its rated efficiency, because a boiler that never gets serviced drifts lower every season it runs.
The old boiler comes out first, and that's when a contractor finds out what the piping actually looks like, not just what the quote assumed. Draining the system, disconnecting the gas and venting, and cutting the new unit in takes up most of the work. Setting the new boiler means matching it to the existing zone valves or circulator pump, then pressure testing the piping for leaks before any gas flows. If the venting is changing from a chimney to sidewall venting, that's new pipe run through a wall, not just a swap at the old flue connection. Once it's firing, the contractor balances the zones and checks that water temperature and pressure hold steady, because a boiler that short cycles on day one will keep doing it. It usually takes a stretch of normal running before you can tell it's holding the temperature it's supposed to.