Cold enough to matter
Winter is the real question here, not summer. Heat runs about eight months a year, October through May, and cooling runs about two, July and August. Overnight lows average 23°F across December, January and February. That's below the point where a standard heat pump starts to struggle. Below 40°F its output falls short of what it's rated for, and below about 35°F it typically needs backup heat to keep up. The average night here sits under both marks.
About 115 nights a year drop to freezing or below here, close to half the nights the heat is even running. That's the stretch where a standard heat pump leans hardest on backup. Only about 2 nights a year reach 0°F, so the deep cold is rare, but the ordinary cold, the 20s and 30s, is most of the winter.
A heat pump built to carry the ENERGY STAR Cold Climate label has to prove something a standard one doesn't: at 5°F it must still make at least 1.75 units of heat per unit of electricity, and hold onto 70 percent of its 47°F capacity, verified by outside testing. In a two-winter field test of cold-climate models in occupied homes, backup heat covered only a small share of the output between 0°F and 35°F, and running on backup alone was rare even above 0°F. That's the gap between a standard heat pump and a cold-climate one, and it's the gap that decides whether it can carry a Kent County winter on its own.