What winter here actually asks of a heat pump
Your heat runs eight months a year here, October through May, and the average overnight low across December, January and February is 26°F. That matters because a standard heat pump starts losing ground before it even gets that cold. Below 40°F it puts out less heat than its rating says. Below about 35°F it often needs backup heat to keep up. Your winter average sits under both marks, and so does every single night here that hits freezing or below, about 100 of them a year.
That doesn't mean a heat pump can't heat your house. It means on roughly 100 nights a year it's working under its rated capacity and likely calling on backup heat to make up the difference, probably electric resistance heat, which costs more to run than the heat pump itself. Only about one night a year here drops to 0°F or colder. The cold that matters in Newport County isn't the rare deep freeze, it's the ordinary 26 to 32 degree night that shows up a hundred times a winter.
A heat pump built to ENERGY STAR's Cold Climate spec is a different machine. To earn that label it has to keep making real heat, at least 1.75 units out for every one unit of electricity in, at 5°F, and hold onto 70 percent of its warm-weather capacity at that temperature. In field testing, prototype cold-climate heat pumps covered most of the heat needed between 0°F and 35°F on their own, with backup heat rarely carrying the load by itself even near 0°F. If you're looking at a heat pump for this county, that distinction, standard versus cold-climate, is the one to ask about before anything else.